FCW 350-G

Tubular wire for gas shielded metal arc hardfacing

Descripción y aplicaciones

Tubular wire for gas shielded metal arc hardfacing.

Low alloy martensitic deposit.

FCW 350-G is used for surfacing and rebuilding parts subjected to impact and high compressive stresses.

Clasificación

EN 14700 DIN 8555
T Fe1 350 P MSG 1 GF 350 P

Análisis químico (%)

C Mn Si Cr Mo Fe
0.15 1.50 0.70 2.00 0.20 Bal.

Propiedades mecánicas

Hardness - 3 Layer deposit
As welded : 350 HB

Gas protector

Current type DC (+)
Shielding gas EN ISO 14175 : M12 / M13 / M21

Parámetros de uso

Diameter [mm] Amperage [A] - Range Voltage [V] – Range Stick Out [mm]
1.2 100-300 24-32 12-25
1.6 150-300 24-32 12-25
2.0 200-400 24-32 12-30
2.4 250-450 24-32 12-30

Posición de soldadura

Suitable as well for downhand as for positional welding by adapting transfer mode and welding parameters as for solid wires.

Embalaje y diámetros

Diámetros [mm] ≤ 2.4 mm ≥ 2.4 mm ≥ 2.4 mm
Embalaje Spool Coil Drum
Peso [Kg] 15 kg 25 kg 330 kg
Descripción - - -
Copyright 2014 - Abracor SA - all right reserved